A bushing that fits wrong rarely fails on day one. The shaft spins a little rough, the bore wears oval over a few months, or the bushing starts turning inside its housing instead of staying put. By then the cause is usually set at the drawing stage. It is one of three things: a wrong fit class on the bore, a wrong fit class on the outside diameter, or stainless specified where a lined or bronze bushing was needed.
Specify a stainless steel bushing in four steps. Press it into the housing with an interference fit (H7/p6 or H7/s6) and run the shaft in it with a clearance fit (H7/g6). Then choose the material from the load, speed and environment, and check pressure times velocity before you assume a dry liner will last.
| Decision | Typical answer | What goes wrong if you miss it |
|---|---|---|
| Outside diameter in the housing | Interference fit, H7/p6 or H7/s6 | The bushing spins in the housing and wears the housing bore |
| Bore around the shaft | Clearance fit, H7/g6 | Too tight binds or galls; too loose develops play early |
| Material | Stainless where corrosion decides; lined or bronze where load or lubrication decides | Wrong material wears fast or corrodes in the wash cycle |
| Pressure times velocity (PV) | Below the liner's rating | A dry liner overheats even when the peak load looks small |
| Grade | 304 dry, 316/316L washdown and marine, 17-4PH higher cyclic load | Pitting, or a wear surface too soft for the duty |
What a Stainless Steel Bushing Actually Does
A bushing is a plain sliding bearing. A shaft rotates or slides directly against the bushing's bore surface, and the bushing takes that friction so the housing bore does not wear instead. That is a different mechanism from a rolling-element bearing or a spherical plain bearing, which carry load through balls, rollers or a ball-and-socket joint. A bushing cannot replace either one without re-checking the load path and the expected motion.
The shaft and the bushing bore are in direct contact, so the fit between them controls most of the service life. It sets how much play develops before it matters, how much heat the friction generates, and how long the surface lasts before replacement.
Two Fits, Not One: Housing Bore and Shaft Bore
A bushing sits between two separate fits, and mixing them up is the most common bore-tolerance mistake. The outside diameter of the bushing fits into the housing bore. The inside diameter of the bushing fits around the shaft. Each one needs a different kind of fit.
The housing-to-bushing fit is almost always an interference fit, such as H7/p6 or H7/s6 under ISO 286's tolerance system. The bushing has to stay fixed under load and under the torque of the shaft turning against it. A loose outside diameter lets the whole bushing spin, which wears the housing instead of the wear part and usually costs more to fix.
The shaft-to-bushing fit is the opposite, a clearance fit. H7/g6 suits a sliding or rotating shaft that must move freely and stay located without wobble. Too tight and the shaft binds or galls on startup. Too loose and the joint develops play almost at once, which shows up as noise or vibration well before the bushing is worn out.
Fit Lookup by Size: Press Fit and Running Fit
The limits below are the ISO 286 deviations for each size band, and the engineering fit article shows worked examples of the same method. Interference is shown as a positive number, clearance as a positive number in its own column, all in micrometres (1 µm = 0.001 mm).
| Nominal size | H7 hole | Press fit H7/p6: interference | Heavier press fit H7/s6: interference | Running fit H7/g6: clearance |
|---|---|---|---|---|
| 10 to 18 mm | 0 to +18 | 0 to 29 | 10 to 39 | 6 to 35 |
| 18 to 30 mm | 0 to +21 | 1 to 35 | 14 to 48 | 7 to 41 |
| 30 to 50 mm | 0 to +25 | 1 to 42 | 18 to 59 | 9 to 50 |
| 50 to 80 mm | 0 to +30 | 2 to 51 | 23 to 78 | 10 to 59 |
| 80 to 120 mm | 0 to +35 | 2 to 59 | 36 to 101 | 12 to 69 |
Worked example: a bushing with a 25 mm outside diameter pressed into an H7 housing bore. At the 18 to 30 mm band, H7/p6 gives 1 to 35 µm of interference, so the bushing is held on paper, although the 1 µm lower limit leaves almost no margin. That spread also means some assemblies press in with light force and others with a good deal more. Where the light end of that spread may not hold the bushing, H7/s6 raises the interference to 14 to 48 µm.
The same 25 mm bushing, bored for a 25 mm shaft at H7/g6, runs with 7 to 41 µm of clearance. The smallest clearance sets how much film or liner the shaft has to work with, and the largest sets how much play you will feel in the joint.
Pressing a bushing in also closes its bore slightly, because the interference fit compresses the bushing wall. Finished bushings are sized to allow for this, but a bushing reamed or reworked after installation needs that compression allowed for again, not re-cut to the catalog dimension.
Concentricity and Roundness Cause Early Failures
Two more dimensions matter beyond the two fits, and both fail the same way: the part passes inspection and still fails early in service.
An off-center bore loads the shaft against one side of the bore instead of around the full circumference. That side takes the wear, and its clearance opens faster than a concentric bushing would ever show. A short bushing absorbs a small eccentricity without much consequence. A long one does not, because the same angular error becomes a larger lateral deflection the farther it runs down the bore.
Roundness fails the same way. A bore can measure correctly at the single diameter an inspector checks and still be oval or tapered along its length. The uneven contact it hides then shows up weeks or months later as wear that looks as if the part was made wrong.
Where Stainless Fits Among Bushing Materials
Picking stainless by default instead of by fit has a cost at both ends. The table sets out the usual choices and where each one stops being right.
| Material | Runs well when | Limit to check |
|---|---|---|
| Solid stainless (304, 316/316L, 17-4PH) | Corrosion resistance has to win: washdown, marine spray, chemical exposure | Needs lubrication, and stainless against stainless is prone to galling |
| PTFE-lined stainless | Grease cannot be used or maintained, as in food and washdown equipment | Lower combined load-and-speed ceiling than a lubricated metal bushing (PV) |
| Bronze or bronze-filled PTFE | Higher load and speed in a dry, indoor, non-corrosive setting | Corrodes in marine and washdown service |
| Brass | Light-duty fittings and instrument housings | Low load capacity, so it deforms under shock |
The two mistakes are mirror images. Specifying stainless on a dry, indoor, shock-loaded pivot where bronze would do gives a bushing that wears faster at a higher price. Specifying bronze for a washdown or marine joint because it was on hand gives a bushing that can pit in the wash cycle, depending on the alloy and the cleaning chemistry. A pitted bushing grows out of round and has to be replaced early.
Stainless earns its place where corrosion resistance has to win over raw load capacity or cost. Outside washdown, marine spray and chemical exposure, the material choice is a cost the application does not need to carry.
Galling Is the Stainless-Specific Risk
Stainless against stainless can gall, and a bushing and shaft in sliding contact are exactly that pairing. The passive chromium oxide layer on austenitic grades (304, 316, 316L) is only a few nanometres thick, and contact stress can break it faster than it reforms. Bare metal then touches bare metal, and the ductile surface cold-welds at the high points. Our thread galling guide explains the mechanism for threads, and the same three properties apply to a bore: high ductility, rapid work hardening and low thermal conductivity.
A press-in of a stainless bushing into a stainless housing is also a sliding contact. Lubricate the press, and drive it at a steady, moderate speed instead of in a single hard hit.
Solid Stainless Versus PTFE-Lined: Check PV
A solid stainless bushing (304, 316/316L or 17-4PH) runs metal-to-metal against the shaft. That gives good dimensional stability and corrosion resistance, but it needs lubrication. Pair it with a shaft of a different hardness or alloy and keep grease in the joint, rather than running two stainless surfaces dry against each other.
A PTFE-lined stainless bushing replaces that contact with a low-friction liner bonded to the bore. PTFE-lined construction runs without added grease and resists moisture and chemicals at the liner surface. The trade-off is a lower load-and-speed ceiling, and that ceiling is a number you can check before specifying.
The pressure-velocity value, PV, is pressure times sliding velocity. Pressure is the load divided by bore diameter times bushing length, and velocity is the shaft surface speed at that diameter. A worked PV example shows the steps.
| Step | Calculation | Result |
|---|---|---|
| Projected area | 1.0 in bore × 2.25 in length | 2.25 in² |
| Pressure | 225 lb / 2.25 in² | 100 psi |
| Velocity | Shaft surface speed | 50 ft/min |
| PV | 100 × 50 | 5,000 |
That is a modest load case, but the liner maker's PV limit is the number that decides it. Put the same load on a shorter bushing or a faster shaft and PV climbs past the liner's rating long before the peak load looks alarming. Check PV against the rating of the liner you intend to use, from the liner maker's data.
Bronze and bronze-filled PTFE tolerate higher combined load and speed than a plain PTFE liner, but bronze corrodes in marine and washdown service, which is usually why stainless was being considered. If an application needs bronze's load capacity more than stainless corrosion resistance, make that trade deliberately.
Choosing a Stainless Grade
304 covers dry or mildly humid indoor equipment where chloride exposure is not a concern. 316 or 316L is the standard choice once washdown, marine spray or a chloride-bearing cleaning chemical is present, because it resists pitting and crevice corrosion better than 304 in that service. 17-4PH trades some of that corrosion margin for higher hardness and wear resistance, which matters more on a bushing carrying higher cyclic load than on one running light, continuous rotation.
Installation and What Wear Patterns Tell You
Press a bushing in with a driver or sleeve sized to its outside diameter, never with a hammer on the end face. A hammer blow mushrooms the edge and can pull the bore out of round right where the fit needs to be tightest, which defeats the tolerance work before the part has run a cycle. Lubricate at startup even on a design rated to run dry afterward, because the first cycles before a liner beds in or a grease film forms are when a dry start does the most damage.
A worn bushing pulled at a service interval tells you what went wrong if you read the wear pattern instead of just replacing it.
| What you see | Likely cause | What to do |
|---|---|---|
| Even wear around the full bore | Normal end of life | Replace on schedule |
| Wear concentrated on one side | Shaft misalignment or an edge load the fit was not made for | Check alignment and concentricity of the bore |
| Deep scoring along the bore | Abrasive contamination in the clearance gap | Add sealing and clean the joint |
| Pitting | Moisture or chemical attack, not mechanical wear | Change the material or the sealing, not just the fit |
Specifying a Bushing for Your Application
A quote moves faster with a short list of specifics instead of a general description of the job. The fit comes from three numbers: the shaft diameter and its tolerance, the housing bore diameter and the expected radial and axial load. The application adds the motion type, which is continuous rotation, oscillation or occasional sliding. It also needs to say whether grease is acceptable or the design needs a dry liner, which stainless grade is already chosen, and any surface finish or heat treatment on the drawing.
Axial load often needs a separate thrust washer or spacer instead of asking the bushing to carry it, because a plain bushing bore is sized for radial fit, not end load. A stainless bushing with a wall thinner than about 1.5 mm also deserves a note on the drawing, because thin walls deflect under clamping and cutting force. Flag that before the job is quoted, not after the first batch measures out of round.
Conclusion
Most bushing failures trace back to one of two decisions made before the part was installed. Either the fit class was wrong on the bore or housing side, or the material was chosen for availability instead of the actual load, speed and environment. Getting both right the first time is cheaper than diagnosing a worn housing bore later. Profab Machine machines stainless steel bushings to the bore tolerance, OD fit and grade your shaft and housing call for, working directly from a drawing or sample rather than a generic catalog size.